Command Receiving Status
The status of the Controller for commands from the host device is as follows:
• Command Standby Status
No command processing is performed and Controller commands can be received.
• Processing Command
The time from when a READ, WRITE, AUTO READ, or AUTO WRITE command is received until a the
response indicating that command processing is completed has been returned.
In this status, the COMMAND PROCESSING ABORT and ABORTcommands only can be received.
• Polling Auto Subcommand Standby Status
The following processing is performed after receiving a POLLING AUTO command.
(1) Processing with the Data Carrier is ended, and the processing results are returned as the response
when a polling processing request command is sent.
(2) The time until processing is aborted when a POLLING PROCESSING ABORT command is sent.
In this status, only the POLLING SUBCOMMAND (REQUEST, ABORT) or ABORT command can be
received.