Setting Methods
Use the provided screwdriver to make switch settings as shown in the following diagram.
• Rotary switch settings
Default Settings
The following table shows the default settings (factory settings).
SW1
SW2
1
O
2
N
3
4
5
6
7
8
SW3 (left)
1
O
2
N
3
4
5
6
7
8
SW4 (right)
Name
SW1
Node number
SW2
Reserved by the system.
SW3-1
Reserved by the system.
SW3-2
Reserved by the system.
SW3-3
Reserved by the system.
SW3-4
Reserved by the system.
SW3-5
Reserved by the system.
SW3-6
Reserved by the system.
CD1D
Not used.
SW3-7
CD2D
RS-485 terminating resistance
SW3-8
Reserved by the system.
SW4-1
Baud rate
SW4-2
SW4-3
Data length
SW4-4
Parity
SW4-5
SW4-6
Number of stop bits
SW4-7
Reserved by the system.
SW4-8
Reserved by the system.
Before Communications
• DIP switch settings
Default setting
0
Node number 0
0
Set to 0.
OFF
Always OFF
OFF
Always OFF
OFF
Always OFF
OFF
Always OFF
OFF
Always OFF
OFF
Always OFF
(Not used.)
OFF
No terminating resistance
OFF
Always OFF
OFF
38,400 bps
OFF
OFF
7 (ASCII7)
OFF
Even
OFF
OFF
2
OFF
Always OFF
OFF
Always OFF
Heat-resistive RFID System
Section 3
Details
39
User's Manual