Amplifier Adjustments

All Models

1

Changing the Display (RUN Mode)

Set the mode
selector to RUN.
RUN
(Factory-set to RUN)

Manual Tuning (Fine Sensitivity Adjustment) in ADJ Mode

Perform fine sensitivity adjustment after teaching and
manual tuning (without using the teaching function) in
the way shown below:
Twin-output Models
First, select the channel to be
adjusted using the channel
selection switch.
CH1
CH2
Set the mode
selector to ADJ.
ADJ
The items displayed in ADJ mode vary with the display
setting in RUN mode.
RUN mode
Digital incident level
Digital percent
Analog value
http://www.ia.omron.com/
Digital incident level (4000 max.)
MODE
2 s
Digital percent
MODE
2 s
Analog incident level and threshold
MODE
2 s
Fine sensitivity adjustment
TEACH
MODE
Sensitivity
Sensitivity
increment with
decrement
threshold
with threshold
decrement
increment
ADJ mode
Digital threshold
Digital percent
Analog value
2

Zero-reset (RUN Mode)

Set the mode
Digital incident level (4000 max.)
selector to RUN.
RUN
To reset to zero again:
To return the initial digital incident level:
*There is no limit on the number of times zero-reset can be used.
3

Initial Reset (SET Mode)

Set the mode
selector to SET.
SET
TEACH
Hold down
both for 5 s.
MODE
Cancel
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
E3X-DA-N
TEACH
1 s
*
TEACH
1 s
TEACH
MODE
Hold down
both for 3 s.
MODE
TEACH
MODE
Execute initial reset
19