CHAPTER 13. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here.

3.4.9 MGI64/MGI16 Board

This part describes the method to solve the problem which occurs in the MGI64/MGI16
board.
3.4.9.1 When the PWR LED Is Turned Off
If the 'PWR' LED on the front panel of the MGI64/MGI16 board is turned off when all the
boards mounted on the OfficeServ 7100 system operate normally, and all the connected
terminals operate normally, check the following or take measures as follows:
Start
Is the CARD ID of the
corresponding slot recognized in
MMC 806?
Yes
Is the LED normally connected?
Yes
Replace the LED or the board.
End
3-46
No
Check +5 V of the 30PIN connector.
No
Replace the LED.