Samsung OFFICESERV 7100 Service Manual page 145

Hide thumbs Also See for OFFICESERV 7100:
Table of Contents

Advertisement

3.4.10.2 Abnormal Operation of PoE
The method to solve the problem when the problem occurs in PoE operation of the PLIM
board is as follows:
Start
Does the power is normally
supplied to the connected
port?
Yes
Does it operate only in a
specific port?
No
End
© SAMSUNG Electronics Co., Ltd.
- Check the LAN cable.
No
- Check the Strap Option.
- Check the connected terminal.
- Replace U1 of PLIMD if the ports #
1, 2, 5, 6 operate abnormally.
Yes
- Replace U2 of PLIMD if the ports #
3, 4, 7, 8 operate abnormally.
- Replace U4 of PLIMD if the ports #9,
10, 13, 14 operate abnormally.
- Replace U6 of PLIMD if the ports #
11, 12, 15, 16 operate abnormally.
OfficeServ 7100 Service Manual
3-51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents