3.4.7 8COMBO Board
This part describes the method to solve the problem which occurs in the 8COMBO board.
3.4.7.1 When the 8COMBO Board Is Not Recognized
The method to solve the problem when the 8COMBO board is not recognized is as follows:
Check if all the specific group of
MP10/11 does not operate.
Does not one group operate?
No
Check if all the boards do not operate.
Do all the boards operate
abnormally?
No
Does the
problem occur only when mounting
the corresponding
SLI board?
No
Repair the corresponding board.
End
© SAMSUNG Electronics Co., Ltd.
Yes
Repair the MP10/11 board.
Yes
- Check again with a normal board.
- Repair the MP10/11 board.
Yes
Check the DATA BUS of the card and
the CARD ENABLE signal.