System Battery - HP ProLiant DL80 Gen9 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL80 Gen9:
Table of Contents

Advertisement

Remove the FlexibleLOM riser board.
7.
To replace the component, reverse the removal procedure.

System battery

If the server no longer automatically displays the correct date and time, then replace the battery that provides
power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
Power down the server (on page 26).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 27).
o
Remove the server from the rack (on page 29).
o
Remove the access panel
4.
Locate the battery on the system board
5.
WARNING:
of the socket, or the tool could slip and damage the socket or the system board.
The computer contains an internal lithium manganese dioxide, a vanadium
("Access
panel" on page 34).
("System board
Do not exert too much force to remove the system battery. The battery could pop out
components" on page 98).
Removal and replacement procedures 62

Advertisement

Table of Contents
loading

Table of Contents