AULIKA
5.2.
Diagnostic mode
SX1
SX3
To access the Diagnostic Mode:
- Turn on the machine
- Press the four function keys in the sequence shown below (SX1, SX2, SX3, SX4) before the
initialization bar is complete
1. Product counters
• Espresso
• Coffee
• Caffè lungo
• American Coffee
• Hot water
• Cappuccino
• Milk coffee
• Hot milk
4. Hotwater flowrate
• 100 ÷ 150
5. Cup temperature
• 75 ÷ 85
SX2
Display
SX4
Menu description in diagnostic mode
MENU
PRODUCT COUNTERS
ERROR COUNTERS
WATER COUNTERS
HOTWATER FLOWRATE
CUP TEMPERATURE
2. Error counters
2.1. Error log
• Error code
• Error index
• Error text
2.2. Errors reset
Rev. 00 / July 2012
05 FAULT FINDING
DX1
DX2
DX3
DX4
3. Water counters
3.1. Descaling cycle
• Since last
• Since second last
• Since third last
• Number of execution
3.2. Brewing unit cleaning
• Number of execution
• Since last
3.3. Since production
3.4. Water filter
• Since last reset
• Number of reset
Page / 08
06