Saeco Aulika Sup 040R Service Manual page 12

Table of Contents

Advertisement

AULIKA
RINSE
When it occurs
N° of pulses
Stoppable
Can be disabled by the user
Can be disabled by Pro-
duction/Service
User-adjustable N° of
pulses
N° of pulses adjustable by
Production/Service
Pulses range
(Min - Max)
GROUNDS DRAWER
Time-out on the grounds drawer
Empty grounds drawer warning after
Empty grounds drawer locking alarm after
(double coffee as the last product delivered)
Grounds counter reset
Water reserve (pulses)
Water reserve adjustable by Production/Service
"Tank absent" alarm
Hardness
Water hardness
1
Soft (up to 7°dH)
2
Medium (7°-14dH)
3
Hard (15°-21°dH)
4
Very hard
(above 21°dH)
The default water hardness is 4. A litre of water corresponds to about 2,000 pulses.
Initial rinse
When the machine is turned on
and the boiler temperature is ≤
Yes, by pressing any key
WATER TANK
"Fill tank" alarm
Water mains
Descaling intervals
Senza filtro anticalcare
240 litres (480,000 pulses)
120 litres (240,000 pulses)
60 litres (120,000 pulses)
30 litres (60,000 pulses)
50°C
130
No
No
No
No
No
Only in the presence of a warning or of the
alarm, provided that the drawer is removed
Rev. 00 / July 2012
02 TECHNICAL DATA
Final rinse
When the machine is turned off
electronically, manually by the user
or automatically after 30' , provided
that at least one coffee has been
dispensed prior to the turning off.
100
Yes, by pressing any key
No
No
No
No
No
Description and values
5 sec.
After 37 grounds
40 grounds
(41 grounds)
for at least 5 sec.
Description
200
No
Yes
No
No
Con filtro anticalcare
480 litres (960,000 pulses)
240 litres (480,000 pulses)
120 litres (240,000 pulses)
60 litres (120,000 pulses)
Page
04
/ 04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents