18. MR-J4-03A6 SERVO AMPLIFIER

18.8.3 Selection example of wires

The following diagram shows the wires used for wiring. Use the wires or equivalent given in this section.
24 V DC power supply
48 V DC power supply
The following shows the wire size selection example.

18.8.4 Circuit protector

Control circuit power supply (24 V DC)
Main circuit power supply (48 V DC)
Main circuit power supply (24 V DC)
Note. For operation characteristics, use an intermediate speed type.
POINT
To comply with the IEC/EN/UL/CSA standard, use the wires shown in appendix
4 for wiring. To comply with other standards, use a wire that is complied with
each standard.
Selection conditions of wire size are as follows.
Construction condition: Single wire set in midair
Wire length: 30 m or less
The voltage drops because of the cable conductor resistance. Especially for
main circuit/control circuit power supply wiring, wire to secure the required input
voltage at servo amplifier input section. It is recommended that the cable length
be as short as possible.
1) Main/control circuit power supply lead
+
-
+
-
Table 18.5 Wire size selection example 1 (HIV wire)
Servo amplifier
MR-J4-03A6
Note. The wire size shows applicable size of the servo amplifier connector and terminal
block. For wires connecting to the servo motor, refer to "Servo Motor Instruction
Manual (Vol. 3)".
Power supply specification
Servo amplifier
CNP1
24
U
0
V
PM
W
E
Wire [mm
1) 24/0/PM/
AWG 16
CP30-BA 1P 1-M 1A
CP30-BA 1P 1-M 3A
CP30-BA 1P 1-M 5A
18 - 81
2) Servo motor power lead
2
]
2) U/V/W/E
(Note)
AWG 19
Circuit protector (Note)