Input Signal Selection; Priority When Forward/Reverse Run Commands Are Entered Simultaneously - Toshiba TOSVERT VF-PS1 Instruction Manual

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

6.2

Input signal selection

6.2.1 Priority when forward/reverse run commands are entered simultaneously

: Priority when forward/reverse run commands are entered
simultaneously
• Function
This parameter allows you to select the direction in which the motor runs when a forward run (F) command
and a reverse run (R) command are entered simultaneously.
1) Reverse run
2) Deceleration stop
[Parameter setting]
Title
Priority when forward/reverse run
commands are entered
simultaneously
[
= (Reverse run)]
Output frequency [Hz]
Set frequency
Set frequency
Forward run signal
Reverse run signal
[
=
(Stop)]
Output frequency [Hz]
Set frequency
Forward run signal
Reverse run signal
Function
If a F command and a R command are entered simultaneously,
the motor will run in the reverse direction.
0
If a F command and a R command are entered simultaneously
the motor will slow down to a stop.
0
F-3
Adjustment range
:Reverse run,
:Stop
Forward run
Time [s]
Reverse run
ON
OFF
ON
OFF
Forward run
Time [s]
Reverse run
ON
OFF
ON
OFF
E6581531
Default setting
6

Advertisement

Table of Contents
loading

Table of Contents