Maximum Temperature Setting - Mira Vigour Installation And User Manual

Thermostatic power shower
Table of Contents

Advertisement

Maximum Temperature Setting

It may be necessary to adjust the maximum temperature for site conditions to make
sure of safe showering from the unit. Make sure that the hot water temperature is at
least 12 °C above the required temperature for correct operation of the thermostatic
power shower.
To reset the maximum outlet temperature follow the sequence below :
1.
Tu r n t h e o u t e r f l o w c o n t r o l
anticlockwise to maximum flow.
2.
Turn the inner temperature control
knob anticlockwise to the maximum
temperature stop. Do not depress
the override button.
3.
Check the shower temperature.
4.
If the maximum temperature requires
adjustment then remove the outer
flow control and the inner temperature
control knobs. Slide the end of the
push-fit release tool under the outer
flow control, lever the outer flow
control and the inner temperature
control knobs off together from the
shower unit.
5.
Remove the small label covering the
retaining screw on the temperature
hub. Unscrew the retaining screw and
remove the temperature hub.
Note! This will void the factory
setting.
Maximum
Flow Position
Maximum Temperature Position
Inner Temperature Control Knob
20
Outer Flow Control
Temperature
Hub
Temperature Hub
Retaining Screw