Maximum Temperature Setting
Before using the shower, the maximum temperature must be checked to make sure
that it is at a safe level. It has been preset to a safe showering temperature under
ideal conditions at the factory, appropriate for most systems. However, site conditions
and personal preference may make it necessary to reset this temperature.
note! Make sure that the hot water temperature is at least 55°C and that there is
sufficient supply.
Caution! Before testing the mixer, make sure that the hot and cold water is flowing
correctly by exercising the temperature selector knob between the cold and hot
stops.
1.
Turn the temperature selector knob to position 7 and test that the temperature
of the water from the shower outlet is hot enough.
2.
If not, depress the override button and carefully rotate towards position 9. If the
water temperature is still not hot enough complete the following procedure.
3.
Rotate the temperature selector knob back to position 7.
4.
Using a suitable screwdriver carefully pry off the concealing cap and unscrew
the fixing screw.
5.
Pull off the temperature selector knob without disturbing the stop assembly.
6.
Replace the temperature selector knob so that the 6 mark is in line with the
stop assembly.
7.
Rotate the temperature selector knob to position 7, wait for the water to
stabilise and test that the temperature of the water from the shower outlet is
hot enough.
If the water temperature is still not hot enough repeat the procedure until a
maximum safe temperature is achieved at position 9.
8.
Refit and tighten the fixing screw, refit the concealing cap.