commIssIonInG
Maximum Temperature Setting
Before using the shower the maximum temperature
must be checked to make sure that it is at a
safe level. It has been preset to approximately
43°c at the factory but due to variations in site
conditions the maximum temperature may need
adjustment.
Note! make sure that the hot water temperature is
at least 55°C and that there is sufficient supply.
1. turn on the mixer to the maximum temperature
and maximum flow (i.e. fully anticlockwise) and
allow the temperature to stabilise.
If the temperature is too hot or too cold adjust
as follows:
2. carefully remove the concealing cap from the
control knob.
3. loosen the control lever grubscrew with the
.5 mm hexagon key (supplied) and pull off
the control lever.
4. If applicable unscrew the hub retaining screw
with a .5 mm hexagon key.
Note! do not remove the hub.
mira minilite
/ mira moto
hub
-
+
mira miniduo
/ mira pace
Flow control
+
lever
.5 mm hexagonal Key
concealing cap
5. Insert the .5 mm hexagon key into the centre
of the spindle and engage with the recessed
temperature adjusting screw.
hub retaining
screw
control lever
-
Grubscrew
6. rotate the hexagon key until the required
maximum temperature is obtained at the
shower. anticlockwise to increase the
temperature, or clockwise to decrease the
temperature (¼ turn = approximately °c).
7. once the desired maximum blend temperature
has been achieved turn off the mixer by
rotating either the hub or flow control lever
(depending on model) fully clockwise.
Note! do not remove the hub.
8. If applicable refit the hub retaining screw.
9. Refit the control lever with the lever at the top
and retighten the grubscrew.
10. check that the shower temperature is
correct.