Endress+Hauser prowirl 70 Technical Information

Vortex flow measuring system prowirl 70 reliable flow measurement of gas, steam and liquids
Hide thumbs Also See for prowirl 70:

Advertisement

Technical
Information
TI 031D/06/e
No. 50072929
Vortex Flow Measuring System
prowirl 70
Reliable Flow Measurement of
Gas, Steam and Liquids
Safe
• Electromagnetic compatibility accord-
ing to IEC 801 and NAMUR
• Sensor and electronics self-diagnos-
tics with alarm functions
• Proven capacitive DSC sensor:
resistant to vibration, thermal shock
and overspeeding
Flexible
• Local, manual configuration possible
with closed housing, even in hazar-
dous areas (Ex i and Ex d)
• Current output simultaneously
available with pulse, alarm or limit
output.
• Programmable current and pulse
simulation
Accurate
• Low measuring uncertainty
<1% of rate (gas/steam)
<0.75% of rate (liquids)
• Wide turndown of up to 45:1
• Every flowmeter is wet calibrated
Universal
• SMART technology permits two-way
digital communication via HART
protocol
• E+H Rackbus interface for connection
to higher level bus systems
• Meter bodies and sensors available in
a wide range of materials
• One standard, compact meter for all
fluids and the complete process
temperature range of -200...+400°C

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser prowirl 70

  • Page 1 Vortex Flow Measuring System Technical Information prowirl 70 TI 031D/06/e No. 50072929 Reliable Flow Measurement of Gas, Steam and Liquids Safe Accurate • Electromagnetic compatibility accord- • Low measuring uncertainty ing to IEC 801 and NAMUR <1% of rate (gas/steam) •...
  • Page 2 • Open collector functions industrial process conditions. • Display mode (local) • System parameters Prowirl 70 Transmitter The new Prowirl 70 transmitter has the following features: Digital Communication • Microprocessor-controlled • SMART technology permits remote • Self-monitoring and diagnosis of...
  • Page 3 • Flange version (DIN: PN 64, 100, 160, 250 and ANSI: Class 600, 900, 1500) • Butt-weld version (ANSI Class 1500) Meter Body Transmitter Prowirl F flanged DN 15...300 Prowirl 70 Compact version Prowirl D Dualsens, flanged DN 15...300 Prowirl W wafer DN 15...150...
  • Page 4 Function Measuring Principle DSC Sensor The operating principle is based on the Vibration Compensation Karman vortex street. When a fluid flows With Prowirl’s DSC sensor, the general past a bluff body, vortices are alter- sensitivity of vortex meters to pipeline nately formed on the sides of that body vibration has been eliminated.
  • Page 5 Planning The following installation recommendations are to be observed when installing Prowirl in the pipeline. In order to maintain the specified accuracy for all fluids and and Installation process conditions, the inner diameters of the meter or meter flange and the process piping should be identical.
  • Page 6 Planning and Installation Site The Prowirl measuring system can Installation basically be mounted in any position, although for extremes of process temperatures, the following orientations are recommended: High process temperatures (e.g. steam): • Horizontal pipeline: install according to C or D •...
  • Page 7 Planning and Minimum Spacing In service cases it may be neccessary Installation to unplug the electronics housing from the pipe stand. When installing, observe the following spacing: • Minimum space required to unplug min. 120 mm the electronics housing: 120 mm; all other sides 100 mm •...
  • Page 8 4000 measuring range. Please contact your • The fluid density determines the upper Endress+Hauser sales organisation for and lower flow limits as described exact dimensioning of the meter for your below (“Minimum and Maximum specific application.
  • Page 9 Measuring Ranges The following tables are given as Your E+H sales organisation will be guideline for measuring ranges, vortex pleased to help you select and dimen- Meter Bodies frequency ranges and K-factors for a sion a flowmeter for your specific typical gas (air at 0 °C and 1.013 bar) application.
  • Page 10 2426...61944 4229...108000 9108...233000 119...2465 305...7427 751...18259 1177...28619 2810...68321 4898...119000 10550...256000 * This table is given as guideline for measuring ranges of Prowirl 70 F (flanged), Measuring range for the standard Prowirl H and Prowirl 70 H (high pressure). high-pressure version...
  • Page 11 Measuring Ranges Density is an important parameter for many calculations, e.g. in corrected volumes. The density of steam as a function of temperature and pressure can be determined Superheated Steam from the following table. and Gas • Volumetric/Mass Flow (V/m) Density of steam [kg/m •...
  • Page 12 Measuring Ranges Example for Liquids To determine: Calculation: Liquids Nominal diameter (DN) for measuring a Select the nominal diameter from the flow of 50 m /h of liquid with a density of measuring range diagram for liquids /h ⇒ DN 50. 0.8 kg/dm and a kinematic viscosity of V = 50 m...
  • Page 13: Electrical Connection

    – 3 +P Operation with HART handheld unit possible. Minimum 250 Ω load resistance needed for HART communication. Connection PFM 2 wire current pulses ENDRESS+HAUSER COMPART DXF 351 Compart DXF 351 3 +P 20 mA unscaled Vortex frequency 1...2850 Hz, 4 mA pulse width 0.18 ms...
  • Page 14 Note: The above barrier is applicable for a completly isolated loop. Otherwise the zener barriers shown below must be used. Connection PFM 2 wire current pulses with Compart flow computer and barriers safe area hazardous area ENDRESS+HAUSER COMPART DXF 351 Compart DXF 351 3 +P Zener barriers e.g. MTL 787S or...
  • Page 15 Electrical Multiple outputs 4...20 mA and Open Collector with intrinsically safe power supply Connection hazardous area Ex i version safe area Intrinsically safe power supply Stahl 9303/15-22-11 4...20 mA Electronic counter Switching repeater Stahl 9250/05-10 Operation with HART handheld unit possible. Minimum 250 Ω...
  • Page 16 Electrical Load R [Ω] Connection Permissible load (with HART: min. 250 Ω) Power supply voltage U Current output load – U – 12 −3 ⋅ 10 0.025 = load resistance = power supply voltage (12...30 V DC) = terminal voltage Prowirl (min. 12 V DC) = output current (25 mA) Note: Where data transfer takes place over the 4...20 mA line via HART protocol...
  • Page 17 Dimensions Prowirl 70 F/D (Flanged / Dualsens) DN 15...150 Remote version (For dimensions of the remote transmit- ter see page 20) (Dotted section: flanged Dualsens version) Pressure rating n x d2 Weight PN 40 17.3 4 x 14 Cl 150 15.7...
  • Page 18 Dimensions Prowirl 70 F/D (Flanged / Dualsens) DN 200...300 • DIN version: Remote version To VSM G 18696-18700 with identical connection dimensions as according to DIN 2501 (For dimensions of the remote transmitter • ANSI version: see page 20) As slip-on-flange according to ANSI B 16.5 Schedule 40...
  • Page 19 Dimensions Prowirl 70 H (High Pressure Version) DN 15...150 Flanged version Butt-weld version Remote version (For dimensions of the remote transmitter see page 20) Weld prep. 22 DIN 2559 Meter body dimensions as for flanged or butt weld versions. Pressure rating...
  • Page 20 Dimensions Remote Transmitter Housing See previous pages for dimensions of the various meter bodies. Flow Conditioner Materials: 1.4435 (316L) Pressure rating Centering diameter Weight [mm] [kg] DIN/ANSI ANSI ANSI PN 10...40 Cl 150 – 54.3 51.1 – 0.04 0.03 ⁄ ") PN 64 Cl 300...
  • Page 21: Technical Data

    Technical Data Flanged Version (DN 15...150) Pressure and Temperature Load Pressure [bar] Diagrams High Pressure Version (DN 15...150) Pressure [bar] Ambient vs. fluid temperatures For instruments in hazardous areas, please note the temperature limitations given in the corresponding Ex-documentation. Fluid temperature [°C]...
  • Page 22 Technical Data Prowirl W/F/H/D Sensor Prowirl W ⇒ wafer version ⇒ flanged version Prowirl F Prowirl H ⇒ high pressure version Prowirl D ⇒ Dualsens version Nominal diameter DN 15...150 (DIN/ANSI) DN 15...300 (DIN/ANSI) DN 15...150 (DIN/ANSI) DN 15...300 (DIN/ANSI) Larger diameters on request Nominal pressure PN 10...40 (DIN 2501), Class 150...300...
  • Page 23 Technical Data Prowirl 70 Transmitter Housing material Cast aluminum, painted Protection type Compact version: IP 65 (DN 60529) Remote version: IP 67 Ambient temperature -40...+80 °C (depending on process temperature) (see page 21) Vibration immunity 1g to 500 Hz (in all directions) Electromagnetic IEC 801 part 3: E = 10 V/m (80 MHz...1GHz);...
  • Page 24 Technical Information Flow Computer Compart DXF 351 (TI 032D/06/e) Ex Documentation Prowirl CENELEC (EX 002D/06/A2) Ex Documentation Prowirl FM (EX 008D/06/A2) Ex Documentation Prowirl CSA (EX 009D/06/D2) Subject to modification Endress+Hauser GmbH+Co. Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel.

Table of Contents