1) The gyrocompass must be type approved for compliance with IMO resolution A.424(XI) (and/
or resolution A.821(19) for installation on HSC). The gyrocompass must also have an update
rate that is adequate for the ship's rate of turn. The update rate must be better than 40 Hz
(HSC) or 20 Hz (conventional vessel).
2) The EPFS must be type approved for compliance with IMO resolution MSC.96(72).
3) The monitor MU-231/MU-270W has been approved by the IMO for CAT 1C and CAT 1HC. If
a different monitor is to be used on IMO vessels, its effective diameter must meet the applica-
ble Category requirements. (Monitor Unit MU-190 is optionally available for the blackbox mod-
els and it is approved by the IMO for CAT 2C and CAT 2HC.)
4) The sensor adapters are Control Serial MC-3000S, Analog IN MC-3010A,
Digital IN MC-3020D and Digital OUT MC-3030D.
5) Characteristics of contact output for Alarm:
• (Load current) 250 mA
• (Polarity) Normally Open: 2 ports, Normally Close: 2 ports
• Serial I/O for alarm is also possible, which complies with IEC 61162-1.