Furuno FAR-3320W Installation Manual page 44

Hide thumbs Also See for FAR-3320W:
Table of Contents

Advertisement

2. WIRING
4. Unfasten the four screws fixing the cable clamp plates (2 pcs.).
Cable clamp plate
for serial cable
5. Pass the serial cable (TTYCYSLA-10) through the cable entrance and the locking
wire saddle circled below. Attach appropriate WAGO connectors (TB802, 8 pin;
TB803, 16 pin, 10 pins used) to the serial cable and attach the connectors to the
RF-TB board. Attach the crimp-on lug (preattached to chassis) shown below to the
drain wire and connect the wire to the chassis.
2-8
Attach crimp-on lug (pre-attached to
chassis) to drain wire and connect
to chassis.
Locking wire saddle
Cable entrance
Cable clamp plate for de-icer
DUMMY PLUG
Dummy plugs are provided to
insert into the unused cable slots.
Insert the plugs for waterproofing.
Cable slot for de-icer
Cable slot for serial cable
TB802
How to connect wires to WAGO connector
Wire
<Procedure>
1. Twist the cores.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
Note: A terminal opener is provided on the
RF-TB Board.
TB803
Press downward.
Terminal opener
WAGO connector
Twist

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Far-3220w-bbFar-3330swFar-3230sw-bb

Table of Contents