2. WIRING
4. Connect the WAGO connectors to the I/O Board, referring to the interconnection
diagram.
5. Bind the cables to the fixing metal in the processor unit with the cable ties (sup-
plied).
6. For the drain wire of the TTYCSLA series cable, attach shrink tubing (local supply)
to drain wire, fasten a crimp-on lug (pre-attached at location shown below) to drain
wire then fasten the wire with a screw.
2-32
Fixing metal
Screws for drain wires
of TTYCSLA cables
Pass drain wire through shrink tubing (local
supply), attach a crimp-on lug (preattached)
to drain wire and fasten wire here.
Example of wiring inside the processor unit
J12 (main control unit)
For J13 and J14 (sub
control units), see the figure
at step 2 in this procedure.