Furuno FAR-3320W Installation Manual page 128

Hide thumbs Also See for FAR-3320W:
Table of Contents

Advertisement

APPENDIX 3 DIGITAL INTERFACE
ACM, ACN - Alert command
$**ACM,hhmmss.ss,aaa,x.x,x.x,ca,a*hh<CR><LF>
$**ACN,hhmmss.ss,aaa,x.x,x.x,ca,a*hh<CR><LF>
1
1. Time (hh=00 to 23, mm=00 to 59, ss.ss=00.00 to 60.99, null)
2. Manufacturer mnemonic code (3 digit alphanumeric code, null)
3. Alert identifier (0 to 9999999)
4. Alert instance (1 to 999999, null)
5. Alert command (A=ACK from ext. equipment, Q=Request from ext.
equipment, O=Responsibility transfer, S=Silence from ext. equipment)
6. Sentence status flag (C should not be null field. Sentence without C
is not a command.)
Information about the use of ACN vs ACM
The alert command sentence formatter ACM is defined in IEC 61924-2 Ed. 1. After Ed. 1 was
released, the ACM is used by other criteria and the IEC technical corrigendum adopted the
sentence formatter ACN to replace the ACM. However, equipment released before the adoption of
the ACN may use ACM. This equipment uses both ACN and ACM.
ALR - Set alarm state
$**ALR,Hhmmss.ss,xxx,A,A,c—c,*hh<CR><LF>
1
1. Time of alarm condition change, UTC (000000.00 - 235960.99)
2. Unique alarm number (identifier) at alarm source (000 - 999)
3. Alarm condition (A=threshold exceeded, V=not exceeded)
4. Alarm acknowledge state (A=acknowledged, V=not acknowledged)
5. Alarm description text (alphanumeric characters, max. 32)
CUR - Current
$**CUR,A,x,x.x,x.x,x.x,a,x.x,x.x,x.x,a,a,*hh<CR><LF>
1 2 3 4
5 6 7 8 9 1011
1. Validity of data (A=valid, V=not valid)
2. Data set number (0 - 9)
3. Layer number (0.0 - 3.0)
4. Current depth in meters (No use)
5. Current direction in degrees (0.00 - 360.00)
6. Direction reference in use (true or relative)
7. Current speed in knots (0.00 - 99.99)
8. Reference layer depth in meters (No use)
9. Heading (0 to 360.00)
10. Heading reference in use (true or magnetic)
11. Speed reference (B=Bottom track W=Water track P=Positioning system)
DBT - Depth below transducer
$**DBT,xxxx.x,f,xxxx.x,M,xxxx.x,F,*hh<CR><LF>
1
2
3
1. Water depth (0.00-99999.99)
2. feet
3. Water depth (0.00-99999.99)
4. Meters
5. Water depth (0.00-99999.99)
6. Fathoms
DPT - Depth
$**DPT,x.x,x.x,x.x,*hh<CR><LF>
1
2 3
1. Water depth relative to the transducer, meters (0.00-99999.99)
2. Offset from transducer, meters (No use)
3. Minimum range scale in use (No use)
AP-8
2
3 4
5 6
2 3 4
5
4
5
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Far-3220w-bbFar-3330swFar-3230sw-bb

Table of Contents