2. Terminal Block

The I/O terminal block, located on the camera module, can be used to develop applications for
alarm input and output, two-way audio, TV-output or a variety of other functions.
Note:
1. You can unplug the terminal block from the camera module for easier wiring.
2. Speakers / microphones with a (built-in) amplifier and external power supply are required.
16 15 14 13
12 11 10
No.
Functions
1
12 VDC Input
2
Digital GND
3
Alarm Out
4
5
Alarm In
6
7
Audio Input (Line-in)
8
Audio GND
To activate the Audio function, the Enable Audio must be checked. See 7.5 Audio in the User's
Manual.
9 8 7
6 5 4
3 2 1
Alarm Output (+)
Alarm COM (-)
Alarm Input (+)
Digital GND (-)
Camera Module
No.
Functions
9
Audio Output (Line-out)
10
Audio GND
11
CVBS Output
12
Digital GND
13
AC24V+
14
AC24V-
15
RS485_A
16
RS485_B