Wiring Control Circuit Terminals

Wire Sizes and Closed-loop Connectors

For remote operation using analog signals, keep the control line length between the Digital Operator or opera-
tion signals and the Inverter to 50 m or less, and separate the lines from high-power lines (main circuits or
relay sequence circuits) to reduce induction from peripheral devices.
When setting frequencies from an external frequency setter (and not from a Digital Operator), use shielded
twisted-pair wires and ground the shield to terminal E (G), as shown in the following diagram.
2kΩ
2kΩ
Terminal numbers and wire sizes are shown in Table 2.9.
Terminals
FM, AC, AM, P1, P2,
PC, SC, A1, A2, A3, +V,
-V, S1, S2, S3, S4, S5, S6,
S7, S8, MA, MB, MC,
M1, M2
P3, C3, P4, C4, MP, RP,
R+, R-, S9, S10, S11,
S12, S+, S-, IG
* 1. Use shielded twisted-pair cables to input an external frequency reference.
* 2. Refer to Table 2.3 Closed-loop Connector Sizes (JIS C2805) (200 V Class and 400 V Class) for suitable closed-loop crimp terminal sizes for the wires.
* 3. We recommend using straight solderless terminal on signal lines to simplify wiring and improve reliability.
-22
2
2kΩ
2kΩ
P
P
Table 2.9 Terminal Numbers and Wire Sizes (Same for all Models)
Termi-
Tightening
nal
Screws
M3.5
0.8 to 1.0
Phoenix
0.5 to 0.6
type
E (G)
M3.5
0.8 to 1.0
Shield terminal
E(G)
V Speed setting power supply, +15 V 20 mA
A1 Master speed reference 0 to 10 V (-10 to 10 V)
A2 Master speed reference 4 to 20
(0 to 10 V, -10 to 10 V)
A3 Auxiliary reference 0 to 10 V (-10 to 10 V)
RP Pulse train input 32 kHz max.
P
P
AC Analog common
-V Speed setting power supply -15 V 20 mA
Fig 2.14
Possible Wire
Sizes
Torque
2
(N•m)
mm
(AWG)
mm
*2
0.75
0.5 to 2
(18)
(20 to 14)
*3
Single wire
:
0.14 to 2.5
0.75
Stranded wire:
(18)
0.14 to 1.5
(26 to 14)
*2
1.25
0.5 to 2
(12)
(20 to 14)
A
Recom-
mended
Wire Type
Wire Size
2
(AWG)
• Shielded, twisted-pair wire
• Shielded, polyethylene-cov-
ered, vinyl sheath cable
(KPEV-S by Hitachi Electri-
cal Wire or equivalent)
*1