Programmable functions
Dispensing neutralising agent via DOS 3
Setting the dosage concentration
The dosage concentration for the neutralising agent must be set according to
the manufacturer's recommendations or the official standards required.
Step
^ Press 0 until E02 appears.
^ Turn the programme selector to
"Intensive".
^ Press ß as many times as necessary or
hold pressed in until the required value
appears in the display, e.g. 0.2.
Dosage concentration set:
Venting the dispensing system
The dispensing system must be vented:
– when the dosage concentration is used for the first time,
– if the chemical agent container runs out and is not refilled in time.
Step
^ Press 0 until E02 appears.
^ Turn the programme selector to
"Universal".
^ Press ß.
^ Exit from programming mode.
Then start the "Rinse" programme.
40
Display / Result
E02
The dosage concentration which
has been programmed in will
appear in the display, e.g. 0.10 =
0.10 %
0.20
The dosage concentration level has
now been set.
Display / Result
E02
d§3
The dispensing system will be
vented automatically. 0 will appear
in the display when the venting
process has finished.
Any agents which are in the wash
cabinet after the venting process
will be diluted before being drained
away.