Wiring - Furuno MU-151C Operator's Manual

Multi-purpose
Hide thumbs Also See for MU-151C:
Table of Contents

Advertisement

2 WIRING

2.1 Wiring
Connect equipment to the MU-151C by referring to the drawings in this section and the
interconnection diagram at the back of this manual. A cable with a connector at both ends is
provided to connect equipment.
General-purpose monitor
To use the MU-151C as a general-purpose monitor, connect equipment with the optional
cable assy, 3COX-2P-6C (5 or 10 m). In this case do not connect a navigator to the NMEA
port. Nav data is output through the D-SUB 25P connector.
RGB IN port
3COX-2P-6C
(5/10 m)
Note: Even when the power switch is off, the electric current flows slightly. Connect the
power line via a double-contact breaker.
Note: If one line of AC is grounded, connect one line to the "C" (Common) terminal and the
other line to the "H" (Hot) terminal.
*: Solder connector SRCN6A13-3S (supplied in installation materials) to the power
cable (DPYCY-1.5 (Japan Industrial Standard) or equivalent).
Sheath
Armor
12-24 VDC (MJ-A3SPF0025-035, 3.5 m)
or 100-220 VAC (DPYCY-1.5*)
Ground Terminal
FCV-1200L/1200LM: INTERFACE UNIT
CH-250, CH-270: INTERFACE UNIT
GD-280/380/680:DISPLAY UNIT
CSH-5L/8L: PROCESSOR UNIT
FR-1500 MARK-3: Connector on RGB BUFFER board in the display unit
CI-68/88: Connect to
CN-A1 port in the control unit with the conversion cable
(66S1242, 0.3 m)
4-6 cm
Solder Side
Screw
Clamp Tighten
set screw
Connector Housing
RGB OUT
RGB OUT
EXT VIDEO
port
or
MONITOR1
DPYCY-1.5
1
2
3
Connect to
"1" and "2".
φ =
11.7 mm
1: AC (H: Hot)
2: AC(C: Cold)
5
port
port
MONITOR2
port
Armor
Sheath
Conductor
2
S = 1.5 mm
φ = 1.56 mm

Advertisement

Table of Contents
loading

Table of Contents