  • Page 3: Safety Instructions

    Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire. Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO agent for service. CAUTION Do not connect/disconnect the signal cable while turning the power on.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS FOREWARD... iii SYSTEM CONFIGURATION... iv EQUIPMENT LISTS ... v 1. MOUNTING ... 1 1.1 Display Unit... 1 1.2 Remote Controller ... 4 2. WIRING ... 5 3. ADJUSTMENTS ... 7 3.1 RGB/DVI Setting ... 7 3.2 VIDEO Setting... 9 3.3 Menu Window Setting ...
  • Page 5: Foreward

    A Word to the Owner of the MU-120C FURUNO Electric Company thanks you for purchasing the MU-120C 12.1” Multi-Purpose LCD Display. We are confident you will discover why the FURUNO name has become synonymous with quality and reliability. For over 50 years FURUNO Electric Company has enjoyed an enviable reputation for quality and reliability throughout the world.
  • Page 6: System Configuration

    FEA-2107 MODEL 1833C series MODEL 1833C-BB series Note: The resolution of MU-120C is SVGA. VGA, XGA and SXGA signal may not be sharp in character or scan line. The TFT LCD is constructed using the latest LCD techniques, and displays 99.99% of its pixels.
  • Page 7: Equipment Lists

    EQUIPMENT LISTS Standard supply Name Display Unit MU-120C Remote Controller RMC-200 Spare Parts* SP19-00101 Installation Materials* CP19-00100 Accessories* FP19-00601 Option Name Type Hanger FP19-00700 3COX-2P-6C Cable Assy DVI-D/D SINGLELINK5M * = See packing list at end of manual. Type Code No.
  • Page 9: Mounting

    1 MOUNTING Refer to the outline drawing at the end of the manual for mounting dimensions. Note: A grass plate covers the LCD. For this reason, handle the unit carefully. 1.1 Display Unit The display unit may be mounted on a desktop (optional hanger required) or flush mounted in a panel.
  • Page 10: Flush Mounting

    Flush mounting See the outline drawing at the end of the manual for mounting dimensions. 1. Remove the LCD cover from the unit. 2. Using the paper template supplied in the installation materials, make a cutout in the mounting location. 3.
  • Page 11 Desktop mounting The display unit can be mounted on a desktop, using the optional hanger, Type: FP19-00700, Code No.: 001-403-240. Name Hanger Knob bolt Self-tapping screw 1. Fasten the hanger to the mounting location with four self-tapping screws (supplied). 2. Screw knob bolts in hanger, set unit to hanger, and tighten knob bolts. 3.
  • Page 12: Remote Controller

    1.2 Remote Controller Write the device name (ex. “FCV-1200L”) for each “signal” key on the sticker supplied with the remote controller. Attach the sticker to the remote controller, at the location shown below. RGB1 VIDEO1 PIP1 RGB2 VIDEO2 VIDEO3 PIP2 PIP3 BRILL MENU...
  • Page 13: Wiring

    2 WIRING Connect external equipment to the MU-120C by referring to the drawings below, the table on the next page and the interconnection diagram at the back of this manual. 12-24VDC 12-24 DVC MJ-A3SPF0025-035 (Supplied) FAR-21X7 series FEA-2107 DVI-D/D SINGLELINK5M DVI-D 2.5C2V or 3C2V...
  • Page 14 Port, cable and connectable equipment Port Name Name 12-24 Power MJ-A3SPF0025- cable DVI-D Cable SINGLELINK5M 3COX-2P-6C RGB1 Analog Cable 3COX-2P-6C RGB2 Prepare the following cable locally. ▪ Connector type: RCA (metal), both ends VIDEO1 ▪ Cable length: shorter than 10 m ▪...
  • Page 15: Adjustments

    3 ADJUSTMENTS Adjust the MU-120C according to the equipment connected. Note that you can adjust the display currently selected, at the DISP selection window. (See section 4.3.) 3.1 RGB/DVI Setting RGB1 and RGB2 screens can be adjusted independently. Also, DVI screen can be adjusted similarly.
  • Page 16 Menu item H_SIZE*** Adjusts the image size horizontally. V_SIZE*** Adjusts the image size vertically. PHASE Adjusts the characters and graphic lines. CONTRAST Increases or decrease contrast level. H_POSITION Moves the image position horizontally. V_POSITION Moves the image position vertically. R_LEVEL Adjusts red color level.
  • Page 17: Video Setting

    3.2 VIDEO Setting VIDEO1, VIDEO2 and VIDEO3 screens; that is, the picture-in-picture windows can be adjusted as below. 1. Press the [MENU] key to show the menu. 2. Press [◄] or [►] to select VIDEO1, VIDEO2 or VIDEO3 as appropriate. RGB1 RGB2 PIP_SIZE...
  • Page 18: Menu Window Setting

    3.3 Menu Window Setting 3.3.1 Adjusting the menu window The menu window can be moved and translucentized on the OSD (On Screen Display) menu. 1. Press the [MENU] key to show the menu. 2. Press the [◄] or [►] key to select OSD. RGB1 RGB2 H_POSITION...
  • Page 19: Changing The Signal Name

    3.3.2 Changing the signal name You can change the signal name which is shown on the DISP or PIP menu, described in the next chapter. It is useful to use the name of the device connected (ex. “FCV-1200L”). For detailed information about these menus, see Chapter 4. 1.
  • Page 20: Remote Controller Setting

    3.4 Remote Controller Setting A remote controller can be set to be operative with a specific display unit, in the case of multiple MU-120C display units. Set the remote controller mode desired on the SYSTEM menu as follows; 1. Press the [MENU] key to show the main menu.
  • Page 21: Operation

    4 OPERATION 4.1 Controls Display unit MENU key Shows the main menu. Arrow keys Selects menu item. Power key: Press the power key ( ) to turn the power on or off. LED: The LED changes color according to signal status as below. Green: The selected signal to be displayed is input correctly from the external device.
  • Page 22 Remote controller Key name RGB1* Shows the RGB1 signal. RGB2* Shows the RGB2 signal. Shows the DVI signal. VIDEO1** Shows the VIDEO1 signal on the entire screen. VIDEO2** Shows the VIDEO2 signal on the entire screen. VIDEO3** Shows the VIDEO3 signal on the entire screen. PIP1*** Shows the VIDEO1 signal in the picture-in-picture window.
  • Page 23: Adjusting Display Brilliance

    4.2 Adjusting Display Brilliance The display brilliance can be adjusted as follows. 1. Press the [BRILL] key on the display unit to show the BRILL adjustment window. BRILL 3. Press the [◄] or [►] key to adjust the brilliance. (Setting range: 1 to 50) You can also adjust brilliance by pressing the [BRILL] key.
  • Page 24: Choosing Source For Main Picture

    4.3 Choosing Source for Main Picture Choose the signal to display on the entire screen as follows: 1. Press the [DISP] key to show the DISP selection window. Signal names can be changed. For detail, see “3.3.1 Changing the signal name”. DISP selection window (default setting) 2.
  • Page 25: Choosing Source For Picture-In-Picture

    4.4 Choosing Source for Picture-in Picture Choose the source for the picture-in-picture window as follows: Note: The size of the picture-in-picture window can be adjusted on the VIDEO1, 2 and 3 menus. For details, see section 3.2. 1. With the RGB1, RGB2 or DVI display shown, press the [PIP] key. The PIP selection window appears.
  • Page 26: Maintenance, Troubleshooting

    5 MAINTENANCE, TROUBLESHOOTING 5.1 Maintenance Routine maintenance Regular maintenance is important for good performance. Check the following on a regular basis to keep the equipment in good operating condition. Check that the connectors at the rear of the display unit are tightly fastened. Check the ground wire and ground terminal for rust.
  • Page 27: Troubleshooting

    Refer any work to a qualified technician. Reason for no picture Ship’s battery voltage too high Fuse has blown. Cable between MU-120C and external equipment has loosened. Power cable has loosened. You can confirm which signals are currently input in the SYSTEM menu.
  • Page 28: Clearing The Memory

    5.3 Clearing the Memory You may want to clear the memory to start afresh with default settings. You can do this as follows: 1. Press the [MENU] key to show the main menu. 2. Press the [►] keys to open the SYSTEM menu. 3.
  • Page 29: Specifications

    Display unit (Front panel): IPX5, Display unit (Rear panel): IP20, Remote controller: IPX0 3.4 Vibration IEC 60945 Ver. 4 4 COATING COLOR Main Unit N3.0 MU-120C maximum, 5 cd/m minimum (0.7 Vp-p , Synchronization: TTL level) SP - 1 MU-120C E2029S02A...