At Unit Connection / Disconnection - JUKI AMS-210EN Series Engineer's Manual

Computer-controlled, cycle machine with input function
Hide thumbs Also See for AMS-210EN Series:
Table of Contents

Advertisement

(22) AT unit connection / disconnection

1. Remove the set screw
Refer to "Second thread tension connection / disconnection.")
2. Draw out the cotter pin
not to drop the washer
3. Lift the AT joint block
type) of the AT link unit (rear)
4. Draw out the AT link unit (front)
5. Remove the two set screws
6. For reassembly, follow the steps of 5. to 1. above.
Procedures of disassembling
of the AT link unit (front)
from the pin block
(H type) or
at that time.
of the AT unit upward to remove the block from the pin block
.
from the plane side (in the direction of the arrow
and take out the AT solenoid unit
F
and take out the second thread tension
(S type) of the AT link unit (rear)
.
E
Close contact
– 35 –
. (3.-(20)
. Be careful
(H type ) or
(S
) and remove it.
E

Hide quick links: