Code
Mode
414
RCV
(Polling)
415
XMT
(Polling)
416
RCV
417
RCV
418
RCV
420
RCV
421
RCV
422
XMT
427
G3
RCV
434 XMT or RCV
436
G3 RX
456
RCV
490
RCV
494
RCV
495
XMT
RCV
501
XMT/
RCV(V.34)
Edition 1.0
Fax Information Codes
Phase
Description of Problem
B
No response received after
transmitting 3rd NSC.
B
Remote side attempted to receive
message from your machine in
polling communication.
D
Receiver did not detect post
command, such as EOP, MPS,
EOM, etc.
C
Receiver returned RTN in
response to post message.
C
Receiver transmitted PIN in
response to PRI-Q from
transmitter. (Transmitting operator
requests voice contact)
B
T1 timer (35 sec.) elapsed without
detecting 300 bps signal.
B
Busy Tone is detected after
sending NSF Signal.
B
Content of NSF (or DIS) or NSC
(or DTC) was invalid.
B
DCN received to NSF/CSI/DIS
transmitted.
B
CD (response from Modem) did
not turn OFF within 180 sec. after
receiver detected FLAG signal.
C
DCN received after transmitting
FTT.
B
Received relay transfer request or
confidential document to distribute
to an end receiving station or all
confidential mailboxes are used.
C
Sum of error lines exceeded the
limit (Function Parameter No. 70)
of 64 lines.
C
Interval between two EOLs was
more than 10 sec. when receiver
received message data.
C
During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
B
Remote unit does not have
compatible Modem.
Password does not match between
transmitter and receiver.
Transmitter is defective. (No original,
document jam, etc.)
Inform the remote side that your
machine does not have the polling
transmission feature.
Transmitter is defective.
Line quality is poor. (RTC signal is
distorted due to line noise)
SC PCB or MJR PCB are defective.
Line quality is poor. (There are
excessive errors in received data)
SC PCB or MJR PCB are defective.
Line quality is poor. (There are
excessive errors in received data)
SC PCB or MJR PCB are defective.
There is wrong incoming call.
(Non-facsimile communication)
Transmitter is defective.
SC PCB or MJR PCB are defective.
Remote station disconnected the line.
Wrong number is dialed.
There is an incompatibility.
The interface is incompatible.
Remote unit is defective.
SC PCB or MJR PCB are defective.
Transmitter is defective or incompatible.
Line quality is poor.
Line quality is poor.
SC PCB or MJR PCB are defective.
Transmitter is defective.
Line quality is poor. (EOL is damaged
due to line noise)
SC PCB or MJR PCB are defective.
Line is disconnected.
Transmitter is defective.
SC PCB or MJR PCB are defective.