No.
Parameter
122 LDAP
123 One Ring Sound
(USA and
Canada Only)
124
Not Used
~
199
Note 1:
Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP or RTN/PIN
Signal
MCF/PIP
RTP/PIP
RTN/PIN
Note 2:
Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 3:
The default setting of parameters depends on the destination's specifications or regulations. Print
the Function Parameter List to confirm the default settings.
Note 4:
Continuous Polling (Station Mode)
This feature allows you to store or add documents into a polled file in memory.
To enable the Continuous Polling feature set Function Parameter No. 003 to "2:Station". The Program
Key [P4] will be assigned with the "Store-4-Polling" name automatically and cannot be changed.
To prepare the document(s) to be polled, simply place the document(s) on the ADF and then press the
Program Key [P4] to store or add the document(s) into a polled file.
(Note:
If a regular polled file ([FUNCTION][3][2]) is stored in memory, the Program Key [P4] for
Continuous Polling will not be accepted.)
Function Parameter Table
Selections
1 = Off
2 = On
1 = Off
2 = On
(Effective from Oct. 2004
Production)
1:128
2:256
0-31
0-63
32-63
64-127
64-127
128-255
Signal
1:5%
MCF/PIP
0-2
RTP/PIP
3-4
RTN/PIN
5-
When LDAP is used, specialize characters may be
displayed as different characters.
Available from May production.
When Function Parameter No. 45 "Ring Detect
Count" is set to 1 Ring, and this parameter is enabled
(On), the machine will only ring once out loud,
answering on the second ring count.
Setting
3:512
4:1024
0-127
0-255
128-255
256-511
256-511
512-1023
Setting
2:10%
3:15%
0-4
0-7
5-9
8-14
10-
15-
142
Function
5:2048
6:Off
0-511
Always
512-1023
-
1024-2047
-
4:20%
0-9
10-19
20-