Vulcan-Hart VC4G Service Manual page 16

Hide thumbs Also See for VC4G:
Table of Contents

Advertisement

VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Fig. 31
3.
Remove screws securing baffle panel and
remove the panel.
Fig. 32
4.
If replacing:
A.
Blower Only - Loosen set screws on blower
hub and using a bearing puller, remove
blower from motor shaft.
1)
Reverse procedure to install and adjust
blower position as outlined under
BLOWER ADJUSTMENT.
B.
Motor - perform step 4A and continue
procedure.
5.
Remove the screws securing the air baffle to the
rear wall at the lower right hand corner.
F24682 Rev. D (1016)
6.
Remove the nuts that secure the motor mounting
plate to the rear wall.
7.
Place a piece of cardboard on the bottom of the
oven cavity to protect its surface from any
damage during motor assembly removal.
8.
Pull the motor assembly into the oven cavity and
place it on the cardboard.
9.
Remove the junction box cover from the motor,
disconnect lead wires and remove the conduit.
10. Remove motor mounting bolts and flat washers
then lift the motor from the mounting plate.
11. Position the replacement motor on the motor
mounting plate and install mounting bolts and
washers. Hand tighten mounting bolts only.
Page 16 of 75
Fig. 33
Fig. 34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents