VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Fig. 27
4.
Remove the ignition module board from the
mounting bracket.
5.
Reverse the procedure to install the replacement
ignition module board.
SPARK IGNITER AND FLAME
SENSE
electrical power to the machine and
follow lockout / tagout procedures.
SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1.
Remove the gas burner as outlined under GAS
BURNER.
2.
Remove the screws securing the ignitor and
flame sense to burner then remove the
assembly.
Fig. 28
3.
Reverse the procedure to install the assembly
and check for proper operation.
Disconnect the
Page 15 of 75
NOTE: Check to ensure the spark gap distance is
approximately 1/8". If the gap appears to be excessive
or poor sparking is occurring then adjust.
PREVOUS PRODUCTION SHOWN
CURRENT PRODUCTION SHOWN

BLOWER AND MOTOR

electrical power to the machine and
follow lockout / tagout procedures.
SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1.
Take out the racks and rack supports.
2.
Remove screws securing the "snorkel" and
remove the snorkel.
Disconnect the