RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations
The minimum components required for a basic horizontal termination are:
1
Horizontal Termination Cap
1
90
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure
to outside surface of wall without siding and add 2 inches.
Alternate
Horizontal Ter-
mination Caps
WARNING:
Do not combine venting components from
different venting systems.
However use of the AstroCap
Regency Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Direct Vent Pro®
Selkirk Direct Temp™
American Metal Products® Amerivent Direct
Metal-Fab™ Sure Seal
Security Secure- Vent®
ICC Excel DirectVent systems.
Use of these systems with the Rigid Pipe
adaptor is deemed acceptable and does not
affect the Intertek WHI listing of components.
The Regency AstroCap
and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as Simpson
TM
Dura-Vent
Direct Vent , American Metal Products Ameri Vent Direct Vent, Security Secure Vent
®
trademark of Regency Fireplace Products. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
and
TM
Flat Wall Installation
Wall Thickness
Vent Length Required
(inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 1-1/2"
9" - 14-1/2"
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
Corner Installation
Wall Thickness
Vent Length Required
(inches)
3-1/4" - 6-3/4"
11" - 14-5/8" Adj. Pipe
7-3/4" - 16-1/4"
17" - 24" Adj. Pipe
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
, Selkirk Direct-Temp. AstroCap
®
Regency Ultimate ™ U900E Gas Fireplace
installation
(inches)
6"
9"
12"
17" - 24" Adj.
(inches)
6" + 12"
9" + 9"
6" + 9"