Vertical Termination - Co-Linear Flex System Into A Masonry Chimney - Regency U900E-NG Owners & Installation Manual

Table of Contents

Advertisement

installation

VERTICAL TERMINATION - CO-LINEAR FLEX SYSTEM INTO A MASONRY CHIMNEY

THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex run-
ning the full length of the chimney. See the
"Venting Arrangements" section for minimum
and maximum heights.
NOTE: Maximum flue height is 30 feet.
The Air Intake pipe must be attached to the inlet air
collar of the termination cap.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Flue Adaptor
30
|
Regency Ultimate ™ U900E Gas Fireplace
Masonry chimneys may take various contours which the flexible liner will accommodate. However,
keep the flexible liner as straight as possible, avoid unnecessary bending.