Regency U900E-NG Owners & Installation Manual page 24

Table of Contents

Advertisement

installation
Description
Attic Insulation Shield 12"
Attic Insulation Shield -
Cold Climates
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Extended Vertical Termination Cap
Chimney Conversion Kit A (USA only)
Chimney Conversion Kit B (USA only)
Chimney Conversion Kit C (USA only)
Chimney Conversion Kit Masonry
(USA only)
Wall Firestop
Colinear Flex Connectors
FPI
946-506/P
Vent Guard (Optional) for AstroCap
510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com
24
|
Regency Ultimate ™ U900E Gas Fireplace
Simpson
Direct Temp™
Direct Vent Pro
®
46DVA-IS
N/A
N/A@ FPI
36"
N/A
N/A
Disc.
4DT-HKA
46DVA-KHA
4DT-HKB
(Changed Components)
Disc.
4DT-VKC
46DVA-VCH
N/A
46DVA-HC
N/A
See 46DVA-HC
4DT-HHC
46DVA-VC
4DT-HVC
46DVA-08A
4DT-SC
46DVA-F12
4DT-ST14
46DVA-F12
4DT-ST36
46DVA-VSS
4DT-VS
N/A
4DT-VSP
46DVA-SNKL
N/A
N/A
N/A
N/A
N/A
N/A
N/A
46DVA-KCA
N/A
46DVA-KCB
N/A
46DVA-KCC
N/A
46DVA-KMC
N/A
46DVA-WFS
N/A
46DVA-ADF
N/A
4" x 6-5/8" Venting
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
Selkirk
American Metal
Products®
Amerivent Direct
4DAIS12
N/A
4DAIS12
N/A
4DHTK2
4DHTKA
4DHTK1
4DHTKB
4DHTK
4DHTK
N/A
N/A
N/A
N/A
4DHC
4DHT
4DVC
4DVT
4DSC
4DSC
4D12S
4DST14
4D36S
4DST36
N/A
4DVS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
946-205
946-208/P
946-523/P
946-206
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Security
Metal-Fab™
Secure- Vent®
Sure Seal
SV4RSA
N/A
SV-SHK
SV-HK
SV-FK
N/A
N/A
SV4CHC-1
SV4CGV-1
SV4FC
SV4STC14
SV4STC36
SV4VS
SV4VS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Vinyl Siding Shield for Riser Vent Terminal
Vent Guard (Optional) for Riser Vent Terminal
AstroCap Horizontal Cap
Vinyl Siding Standoff for AstroCap
ICC Excel
Direct
N/A
TM-4AS
TM4-HTK
TM4-HTK
N/A
TM-4VT
TM-4DHT
TM-4HT
N/A
TM-SC
TF-4FA
TF-4FB
TM-VSS
N/A
TM-4ST14
TM-4ST36
TM-4DS
N/A
TM-4CA6
TM-4CA7
TM-4CA8
N/A
TM-4TR
N/A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U900e-lpU900e

Table of Contents