maintenance

FAN SERVICE

PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO
ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS
SUPPLY IS TURNED OFF.
1. Remove faceplate, inner frame, glass door, front trim piece and inner
panels - see instructions in this manual.
2. Remove logs.
3. Remove burner side panels by lifting out as shown in Diagram 1.
Diagram 1 - Burner Side Panels
4. Remove enamel side panels by loosening the 2 screws (1 per side) in
locations noted and remove the 2 clips.
5. Remove front lip by removing 2 screws located on firebox floor.
6. Remove rear log tray by removing 3 screws as shown in Diagram 2 below.
Diagram 2 - Side Panel, Front Lip & Log Tray
52
|
Regency Ultimate ™ U900E Gas Fireplace
Side Panel Screws
Log Tray Screws
Front Lip Screws
Screw Locations
7. Remove burner by removing 2 screws in locations shown below.
Diagram 3 - Burner Screw Locations
8. Remove access panel by removing eight(8) screws in locations shown in
Diagram 4.
Diagram 4 - Access Tray screws
9. Remove two (2) screws to remove fan shown in Diagram 6.
10.
Reverse steps to reinstall fan.