System Data - Siemens SINAMICS S120 Manual

Modular motion control drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

2.10

System data

General technical system data
Electrical data
Line voltages and power ranges
Line system configurations
Line frequency
Output frequency
Line power factor fundamental
factor
Efficiency
Control method
Fixed speeds
Skipped speed ranges
Braking operation
Output data in the basic version, performance enhancement possible with parallel connection.
1)
Mechanical data
Degree of protection
Safety class
Cooling method
Shock protection
Cabinet system
Paint finish
Compliance with standards
Standards
CE marking
RFI suppression
Cabinet Modules
Manual, (GH5), 05/2010, A5E03263538A
380 ... 480 V 3 AC, ±10 % (-15 % < 1 min), 1.6 ... 800 kW
500 ... 690 V 3 AC, ±10 % (-15 % < 1 min), 55 ... 1200 kW
TN/TT supplies or isolated-neutral supplies (IT supplies)
47 ... 63 Hz
0 ... 300 Hz (>100 / 160 Hz, take derating into account)
Basic Line Modules:
> 0.96
> 99.0 %
Servo control, vector control with and without encoder or V/f control
15 fixed speeds plus 1 minimum speed, programmable
4, parameterizable
With regenerative feedback or by additional Braking Modules and braking resistors
IP20, IP21, IP23, IP43 and IP54
(with options M26 and M27, side panels on the right and left respectively)
Safety class I acc. to EN 61800-5-1
Forced air cooling AF to EN 60146
BGV A 3 acc. to EN 50274
Rittal TS 8, doors with double-bit key, tripartite base plates for cable inlet
RAL 7035 (indoor requirements)
EN 50274, EN 60146-1, EN 60204-1, EN 60529, EN 61800-2, EN 61800-3, EN 61800-
5-1
To EMC Directive No. 2004/108/EC and Low-Voltage Directive No. 2006/95/EC
To EMC product standard for variable-speed drives (EN 61800-3); second environment
(first environment on request)
Smart Line Modules:
> 0.96
> 98.5 %
System overview
2.10 System data
1)
1)
Active Line Modules:
variable (set in factory to
cos φ =1)
> 97.0 %
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents