Siemens SINAMICS S120 Manual page 202

Modular motion control drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet Modules
5.6 Chassis format Motor Modules
Order no.
Weight, approx. (standard version)
Frame size
Rated output of a typ. 6-pole standard induction motor based on I
1)
Rated output of a typ. 6-pole standard induction motor based on I
2)
The base load current I
3)
The base load current I
4)
For the interdependency of pulse frequency and max. output current/output frequency, see SINAMICS - Low-Voltage
5)
Configuration Manual on the customer DVD supplied with the device.
The specified power loss equals the maximum value at 100 % capacity utilization. The value in normal operation is
6)
lower.
Total of all motor cables. Longer cable lengths for specific configurations are available on request, see SINAMICS -
7)
Low-Voltage Configuration Manual on the customer DVD supplied with the device.
With option L08 (motor reactor):
8)
- Frame size HX/JX →Supplementary cabinet 600 mm wide
With option L10 (dv/dt filter plus VPL):
- Frame size FX/GX/HX/JX →Supplementary cabinet 600 mm wide
With option L34 (circuit breaker at output side):
- Frame size FX/GX →Supplementary cabinet 400 mm wide
- Frame size HX/JX →Supplementary cabinet 600 mm wide.
The cabinet height increases by 250 mm with IP21 degree of protection, and by 400 mm with IP23, IP43 and IP54
9)
degrees of protection.
202
6SL3720-
kg
is based on a duty cycle of 110% for 60 s or 150% for 10 s with a duty cycle duration of 300 s.
L
is based on a duty cycle of 150% for 60 s or 160% for 10 s with a duty cycle duration of 300 s.
H
1TE37-
1TE38-
1TE41-
5AA3
4AA3
0AA3
490
490
700
HX
HX
JX
or I
at 3 AC 50 Hz 400 V.
L
H
or I
at 3 AC 60 Hz 460 V.
L
H
Manual, (GH5), 05/2010, A5E03263538A
1TE41-
1TE41-
2AA3
4AA3
700
700
JX
JX
Cabinet Modules

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents