Theory of Operation Ver. 1.0 Apr. 2005
10. PC Drum charging
• The surface of the PC Drum is deposited with charge through corona discharge from the
PC Drum Charge Corona.
• The grid mesh interposed between the corona wire and the PC Drum ensures that a uni-
form charge is deposited across the entire surface of the PC Drum.
• The corona unit has a comb electrode that discharges only toward the grid mesh. This
results in the amount of ozone produced being smaller than with the wire electrode.
Grid Mesh
10. PC Drum charging
Comb Electrode
4021M011AA