Transformer Information; Heater Staging; Manufactured Housing; Transformer Connections - Carrier fb4cnf024 Installation Instructions Manual

Table of Contents

Advertisement

THERMOSTAT
[27b
[]
FAN COIL
(CONTROL)
HEAT PUMP
(CONTROL)
R
G
c
W2
E
W 3
S
C
R
C
W2
o
Y
Fig. 13 - Wiring
Layout
Heat Pump
Unit
(Cooling
and 2-Stage
Heat with
1 Outdoor
Thermostat)
FAN COIL
(CONTROL)
R
G
_
BR_
C
_
WH]
W2
_
BLU
w3
v!o
ODT
ODT
THERMOSTAT
HEAT
PUMP
(CONTROL)
R
C
W2
O
Y
A94061
EMERGENCY
HEAT
RELAY
A94062
Fig. 14 - Wiring
Layout
Heat
Pump
Unit (Cooling
and
2-Stage
Heat with 2 Outdoor
Thermostats)
[]
[]
[]
[]
THERMOSTAT
FAN COIL
(CONTROL)
HEAT PUMP
(CONTROL)
R
C
,[ w2
O
v
A0a088
Fig. 15 - Wiring
Layout
Heat Pump
Unit
(Cooling
and 2-Stage
Heat for Manufactured
Housing)
Refer to outdoor
unit wiring
instructions
for any additional
wiring
procedure
recommendations.
Transformer
Information
Transformer
is factory-wired
for
230v
operation.
For
208v
applications,
disconnect
the black
wire from
the 230v
terminal on
transformer
and connect it to the 208v terminal. (See Fig. 16.)
RED
YEL
Fig. 16 - Transformer
Connections
Heater
Staging
A05182
PROPERTY
DAMAGE
HAZARD
Failure
to follow
this caution
may
result
in
product
or
property
damage.
If W2, W3,
and E on any 3 stage
heater
(18,
20, 24, or
30kW)
are
individually
connected
as
with
outdoor
thermostats
or any other situation,
emergency
heat relay must
be used.
This relay is in kit Part No. KHOT0201SEC
and is
normally
used
with
kit Part
No.
KHAOT0301FST
for 2
outdoor
thermostat
systems.
The controls
are factory
circuited
for single-stage
operation.
For
2-stage
operation,
use
outdoor
thermostat
kit
Part
No.
KHAOT0301FST,
and
for
3-stage
use
both
kits
Part
No.
KHAOT0201SEC
and KHAOT0301FST.
When
2 stages
are desired,
cut W3 at the W2 wire nut, strip and
reconnect
per the thermostat
kit instruction.
(See Fig. 14.) When 3
stages
are desired,
cut the W2 wire nut off and discard.
Strip W2,
W3, and E and reconnect
per thermostat
kit instructions.
(See Fig.
14.)
NOTE:
When 3 stages are used or anytime
the E terminal is not
tied to W2, the emergency
heat relay, part of outdoor
kit Part No.
KHAOT0201SEC
nmst be used.
C. Manufactured
Housing
In
manufactured
housing
applications,
the
('ode
of
Federal
Regulations,
Title
24, Chapter
XX,
Part 3280.714
requires
that
supplemental
electric
heat be locked
out at outdoor
temperatures
above 40°F (4°C),
except
for a heat pump
defrost
cycle.
Refer to
Fig. 15 for typical
low voltage
wiring
with outdoor
thermostat.