Capacitance Specifications

Absolute Uncertainty, tcal
±(% of output + floor)
Range
90 days
0.19 to
0.38 + 0.01 nF
0.3999 nF
0.4 to
0.38 + 0.01 nF
1.0999 nF
1.1 to
0.38 + 0.01 nF
3.2999 nF
3.3 to
0.19 + 0.01 nF
10.9999 nF
11 to
0.19 + 0.1 nF
32.9999 nF
33 to
0.19 + 0.1 nF
109.999 nF
110 to
0.19 + 0.3 nF
329.999 nF
0.33 to
0.19 + 1 nF
1.09999 μF
1.1 to
0.19 + 3 nF
3.29999 μF
3.3 to
0.19 + 10 nF
10.9999 μF
11 to
0.30 + 30 nF
32.9999 μF
33 to
0.34 + 100 nF
109.999 μF
110 to
0.34 + 300 nF
329.999 μF
0.33 mF to
0.34 + 1 μF
1.09999 mF
1.1 to
0.34 + 3 μF
3.29999 mF
3.3 to
0.34 + 10 μF
10.9999 mF
11 to
0.7 + 30 μF
32.9999 mF
33 to
1.0 + 100 μF
110 mF
[1]
The output is continuously variable from 190 pF to 110 mF.
[2]
Specifications apply to both dc charge/discharge capacitance meters and ac RCL meters. The maximum allowable peak voltage
is 3 V. The maximum allowable peak current is 150 mA, with an rms limitation of 30 mA below 1.1 μF and 100 mA for 1.1 μF and
above.
The maximum lead resistance for no additional error in 2-wire COMP mode is 10 Ω.
[3]
7/11
±5 °C
Resolution
1 year
0.5 + 0.01 nF
0.1 pF
0.5 + 0.01 nF
0.1 pF
0.5 + 0.01 nF
0.1 pF
0.25 + 0.01 nF
0.1 pF
0.25 + 0.1 nF
0.1 pF
0.25 + 0.1 nF
1 pF
0.25 + 0.3 nF
1 pF
0.25 + 1 nF
10 pF
0.25 + 3 nF
10 pF
0.25 + 10 nF
100 pF
0.40 + 30 nF
100 pF
0.45 + 100 nF
1 nF
0.45 + 300 nF
1 nF
0.45 + 1 μF
10 nF
0.45 + 3 μF
10 nF
0.45 + 10 μF
100 nF
0.75 + 30 μF
100 nF
1.1 + 100 μF
10 μF
Allowed Frequency or
Charge-Discharge Rate
Typical
Min and Max
to Meet
Max for
< 0.5 % Error
Specification
10 Hz to 10 kHz
20 kHz
10 Hz to 10 kHz
30 kHz
10 Hz to 3 kHz
30 kHz
10 Hz to 1 kHz
20 kHz
10 Hz to 1 kHz
8 kHz
10 Hz to 1 kHz
4 kHz
10 Hz to 1 kHz
2.5 kHz
10 to 600 Hz
1.5 kHz
10 to 300 Hz
800 Hz
10 to 150 Hz
450 Hz
10 to 120 Hz
250 Hz
10 to 80 Hz
150 Hz
0 to 50 Hz
80 Hz
0 to 20 Hz
45 Hz
0 to 6 Hz
30 Hz
0 to 2 Hz
15 Hz
0 to 0.6 Hz
7.5 Hz
0 to 0.2 Hz
11
5520A Operator
Typical
Max for
< 1 % Error
40 kHz
50 kHz
50 kHz
25 kHz
10 kHz
6 kHz
3.5 kHz
2 kHz
1 kHz
650 Hz
350 Hz
200 Hz
120 Hz
65 Hz
40 Hz
20 Hz
10 Hz
3 Hz
5 Hz