5. TROUBLESHOOTING
Any error during data link can be checked by the ERR. LED of the master
station.If the ERR. LED of the master station is lit or flickers due to a data link
error, first refer to the user's manual of the master module used and check the
data link states of the other stations in the CC-Link system.
If there are many stations in data link error on the downstream side of the
AJ65SBT-RPS/RPG (the side on which the master station does not exist), the
AJ65SBT-RPS/RPG may be faulty. Therefore, make a line test again (refer to
Section 4.8).
Master station
Downstream side of
AJ65SBT-RPS/RPG
6. EXTERNAL DIMENSIONS DIAGRAM
The external dimensions diagram of the AJ65SBT-RPS/RPG module is shown
below.
109 (4.29
2-4.5 @@ 5.1 Mounting hole
PW
DA
DG
+24V
DB
SLD
Remote
Repeater
I/O station
Repeater
Remote
I/O station
118(4.65)
+1
+0.04
) (Mounting pitch)
0
0
(M4 mounting screw)
24G
(FG)
Intelligent
device station
Intelligent
device station
Perform a line test!
20(0.79)
4 2 1
ON
IN
OUT
24
Remote
device station
Remote
device station
Unit : mm (inch)
7.9(0.31)
DIN rail