Serial Interfacing (RS-422A)

To construct a cable for an RS-422A serial configuration you will need:
DC-37P equivalent 37- pin plug, shell equivalent to DC-C1-J16
Beldon (or equivalent) SHIELDED cable with twisted pair conductors. Must be
UL and CSA approved. The cable MUST be shielded.
The printer has a 37-pin DC-37S receptacle.
Pin description
Pin no
Signal
1
Shield
3*
Supervisory
send data
21
Supervisory
send data
4
Send data
22
Send data
6
Receive
data
24
Receive
data
7*
Request to
send
25
Request to
send
9
Clear to
RS.
Printer
27
Clear to
Code
Direction
SHILD
SSD
From
printer
SSD
From
printer
SD
From
printer
SD
From
printer
RD
To printer
RD
To printer
RS
From
printer
RS
From
printer
CS+
To printer
CS-
To printer
Connection Function
Cable shield
A-A'
Signal to indicate
printer cannot
receive data in
B-B'
Ready/Busy
protocol
A-A'
Data from printer
B-B'
A-A'
Data to printer
B-B'
A-A'
Signal to indicate
printer cannot
receive data in
B-B'
Ready/Busy
protocol
A-A'
Reply signal to
send
transmits data
after confirming
B-B'
this signal as a
Space
C – 7