IVT 09LR-N Service Manual page 42

Split type air to air heat pump
Table of Contents

Advertisement

12LRN
Problem
Outdoor
symptom
unit indi-
cation
(LED1)
Indoor unit
Lighting
     Timer (Orange)
operates.
or OFF
Outdoor unit
does not
operate.
Indoor and
Lighting
     Timer (Orange)
outdoor units
or OFF
do not oper-
ate.
Indoor and
Normal
     Timer (Orange)
outdoor units
blinking
do not oper-
or OFF
ate.
Indoor and
Normal
     Timer (Orange)
outdoor units
blinking
do not oper-
or OFF
ate.
Indoor unit
Malfunc-
tion No.
Lamp
Main Sub
18
0
Operation (Red)
Plasmacluster
(Blue)
1
Operation (Red)
Plasmacluster
(Blue)
19
0
  Operation (Red)
Plasmacluster
(Blue)
20
0
Operation (Red)
Plasmacluster
(Blue)
Content of diagnosis
Main
Sub
Wiring
Serial short-cir-
between
cuit
units
Serial erroneous
wiring
Indoor unit
Indoor unit fan
fan
error
Indoor unit
EEPROM data
control PCB
error
3 – 20
Check point
(1) Check the wiring
(1) Correct the wiring.
between units.
(1) Check the wiring
(1) Correct the wiring.
between units.
(1) Check the indoor fan
(1) Replace the indoor
motor for proper
fan motor.
rotating operation.
(Check fan lock.)
(2) Check the lead wire
(2) Replace the indoor
of the indoor fan
fan motor.
motor for open-cir-
cuit.
(3) Check connector of
(3) Correct the instal-
the indoor unit fan
lation of the indoor
motor for secure
fan motor connec-
installation.
tor.
(4) (1) (2) (3):Normal
(4) Replace the indoor
unit control PCB.
(1) (EEPROM read data
(1) Replace the indoor
error)
unit control PCB.
Action

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

12lr-n