IVT 09LR-N Service Manual page 26

Split type air to air heat pump
Table of Contents

Advertisement

12LRN
2. Outdoor unit
Item
Mode
Compressor cham-
Cooling
ber thermistor
Dehumidifying
(TH1)
Heating
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
Outside air temper-
Auto
ature thermistor
(TH3)
Cooling
Dehumidifying
Heating
Suction pipe ther-
Cooling
mistor (TH4)
Dehumidifying
Heating
2-way valve ther-
Cooling
mistor (TH5)
Dehumidifying
Heating
Control operation When resistance
is low (tempera-
ture judged higher
than actual)
Expansion valve
Compressor oper-
control and com-
ates, but room does
pressor protection
not become cool or
warm (expansion
valve is open).
Outdoor unit heat
Compressor oper-
exchanger over-
ates at low speed
heat prevention
or stops.
Expansion valve
Defrosting opera-
control
tion is not activated
Defrosting
as needed, and
frost accumulates
on outdoor unit
(expansion valve is
closed).
Operation mode
Cooling mode is
judgment
activated even if
room temperature
is low.
Operation not
Normal operation.
affected
Rating control
Defrosting opera-
Defrosting
tion is activated
unnecessarily.
Expansion valve
Compressor oper-
control
ates, but room does
not become cool
(expansion valve is
open).
Expansion valve
Compressor oper-
control
ates, but room does
not become warm
(expansion valve is
open).
Expansion valve
Frost accumulates
control
on indoor unit evap-
orator and room
does not become
cool (expansion
valve is closed).
Operation not
Normal operation.
affected
3 – 4
Short-circuit
When resistance
is high (tempera-
ture judged lower
than actual)
Compressor high
Layer short-circuit
temperature error
or open-circuit may
indication.
result in compres-
sor in normal oper-
ation.
Outdoor unit ther-
Normal operation.
mistor short-circuit
error indication.
Outdoor unit ther-
Defrosting opera-
mistor short-circuit
tion is activated
error indication.
unnecessarily, and
room does not
become warm
(expansion valve is
open).
Outdoor unit ther-
Heating mode is
mistor short-circuit
activated even if
error indication.
room temperature
is high.
Outdoor unit ther-
Normal operation.
mistor short-circuit
error indication.
Outdoor unit ther-
Defrosting opera-
mistor short-circuit
tion is not activated,
error indication.
and frost accumu-
lates on outdoor
unit.
Outdoor unit ther-
Frost accumulates
mistor short-circuit
on evaporator inlet
error indication.
section, and room
does not become
cool (expansion
valve is closed).
Outdoor unit ther-
Frost accumulates
mistor short-circuit
on expansion valve
error indication.
outlet section, and
room does not
become warm
(expansion valve is
closed).
Outdoor unit ther-
Compressor oper-
mistor short-circuit
ates, but room does
error indication.
not become cool
(expansion valve is
open).
Outdoor unit ther-
Normal operation.
mistor short-circuit
error indication.
Open-circuit
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.
Outdoor unit ther-
mistor open-circuit
error indication.