IVT 09LR-N Service Manual page 3

Split type air to air heat pump
Table of Contents

Advertisement

2. 09LR-N
ITEMS
Rated cooling capacity (Min– Max.)
Rated heating capacity (Min–Max.)
Moisture removal (at cooling)
Electrical data
Phase
Rated frequency
Rated voltage
Cool
Rated current ☆
(Min - Max.)
Heat
Cool
Rated input ☆
(Min - Max.)
Heat
Cool
Power factor ☆
Heat
Maximum operating current
Compressor
Type
Model
Oil charge
Refrigerant system
Evaporator
Condenser
Control
Refrigerant (R410A)
De-lce system
Noise level
High
(at cooling)
Low
Soft
Fan system
Drive
Air flow quantity
High
(at cooling)
Low
Soft
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Drain piping mm
Others
Safety device
Air filters
Net dimensions
Width
Height
Depth
Net weight
NOTE: The conditions of star"✩" marked item are based on 'EN14511'.
MODEL
INDOOR UNIT
09LR-N
kW
2.50(1.40 - 3.00)
kW
3.20 (1.40 - 5.00)
Liters/h
Hz
V
220-240
A
2.9 (2.0 - 3.9 )
A
3.4( 1.7 - 6.3 )
W
570 (350- 800)
W
700 (290 - 1300)
%
%
A
Hermetically sealed rotary type
5RS102XBE01
RB68A 320cc
Louver Fin and Grooved tube type
Corrugate Fin and Grooved tube type
Expansion valve
1140g
Micro computer controled reversed systems
dB(A)
42
dB(A)
dB(A)
26
Direct drive
m3/min.
9.4
m3/min.
7.0
m3/min.
4.7
Cross flow fan
Flare type
3/8", 1/4"
O.D 16
Compressor: Thermistor
Fan motors: Inherent thermistor
Fuse, Micro computer control
Polypropylene net (Washable)
mm
770
mm
260
mm
248
kg
9
1 – 2
OUTDOOR UNIT
0.8
1
50
85
90
8.1
45
28.3
Propeller fan
780
540
265
34
12LRN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

12lr-n