RM-42
RF Troubleshooting and Manual Tuning Guide
Span:
Reference level offset:
Reference level:
Input attenuation:
Resolution bandwidth:
Video bandwidth:
Sweep time:
Detector:
Average:
Trigger:
Trigger level:
Marker:
Marker step:
6.
After setting the spectrum analyzer, click OK.
7.
Measure the power levels with a marker.
Take the first measurement from 250 us after the trigger, the second from 750 us, the third on 1225 us
and so on in every 500 us until the table is filled.
Note:
It must be possible to measure power levels down to –68 dBm. The measured power levels must
be monotonously decreasing.
Make sure that the marker is not measuring the level of noise spike on lower levels.
9241872 (Issue 1)
Company Confidential
Copyright ©2005 Nokia. All Rights Reserved.
0 Hz
Cable attenuations + adapter attenuation
14 dBm
(20 dB) To minimize the noise floor, manually
select as small value as possible for the mentioned
reference level .
30 kHz
30 kHz
20 ms
RMS detector
No
Video
0 dBm
250 us
500 us
Nokia Customer Care
Page 7–49