Cisco Catalyst 4500 Series Configuration Manual page 1422

Release ios xe 3.3.0sg and ios 15.1(1)sg
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Configuring Ethernet CFM
Command
Step 3
Switch(config-ip-sla-ethernet-monitor)# type
echo domain domain-name vlan vlan-id
[exclude-mpids mp-ids]
or
type jitter domain domain-name vlan vlan-id
[exclude-mpids mp-ids] [interval
interpacket-interval] [num-frames number-of
frames transmitted]
Step 4
Switch(config-ip-sla-ethernet-echo)# cos
cos-value
Step 5
Switch(config-ip-sla-ethernet-echo)# owner
owner-id
Step 6
Switch(config-ip-sla-ethernet-echo)#
request-data-size bytes
Step 7
Switch(config-ip-sla-ethernet-echo)# tag text
Step 8
Switch(config-ip-sla-ethernet-echo)# threshold
milliseconds
Step 9
Switch(config-ip-sla-ethernet-echo)# timeout
milliseconds
Step 10
Switch(config-ip-sla-ethernet-echo)# exit
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
63-22
Chapter 63
Purpose
Configures the automatic Ethernet operation to create echo
(ping) or jitter operation and enters IP SLAs Ethernet echo
configuration mode.
Enter type echo for a ping operation or type jitter for
a jitter operation.
For mpid identifier, enter a maintenance endpoint
identifier. The range is 1 to 8191.
For domain domain-name, enter the CFM domain
name.
For vlan vlan-id, the VLAN range is from 1 to 4095.
(Optional) Enter exclude-mpids mp-ids to exclude the
specified maintenance endpoint identifiers.
(Optional—for jitter only) Enter the interval between
sending of jitter packets.
(Optional—for jitter only) Enter the num-frames and
the number of frames to be sent.
(Optional) Sets a class of service value for the operation.
(Optional) Configures the SNMP owner of the IP SLAs
operation.
(Optional) Specifies the protocol data size for an IP SLAs
request packet. The range is from 0 to the maximum size
allowed by the protocol being used; the default is 66 bytes.
(Optional) Creates a user-specified identifier for an IP
SLAs operation.
(Optional) Specifies the upper threshold value in
milliseconds for calculating network monitoring statistics.
The range is 0 to 2147483647; the default is 5000.
(Optional) Specifies the amount of time in milliseconds
that the IP SLAs operation waits for a response from its
request packet. The range is 0 to 604800000; the default
value is 5000.
Returns to global configuration mode.
Configuring Ethernet OAM and CFM
OL-25340-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents