Temperatures

Optimum performance is obtained when temperature differentials of 20°C or more
exist between blend and either supply. Blend control accuracy will begin to diminish
at temperature differentials below 12°C.
Blend Temperature Range: Between ambient cold and approximately 60°C,
according to hot water supply temperature.
Thermostatic Control Range: Approximately 25-60°C.
Optimum Thermostatic Control Range: 30-50°C.
Recommended Minimum Cold Water Supply Temperature: 1°C.
Recommended Maximum Hot Water Supply Temperature: 85°C.
Note! The shower control can accept temporary temperature excursions above 85°C
without damage, however operation at such elevated supply temperatures is not
recommended. For reasons of general safety, hot water storage temperatures should
ideally be maintained at between 60-65°C where serving ablutionary applications.
Minimum temperature differential between hot and outlet temperature: 10°C.
Flow Control
The Mira Form shower control has integral flow control; no other user-operated flow
control should be used with this shower control.
Connections
The shower control inlet connections are 15 mm compression (nuts and olives are
provided).
Hot (H) and Cold (C) inlets are clearly marked for the shower control and must be
connected as described in the INSTALLATION section.