Mira FORM Installation & User Manual page 31

Shower control
Table of Contents

Advertisement

Removing/Fitting Knob and Concealing Plate Assemblies
Removing the Knob Assembly
1.
Rotate the flow knob fully clockwise
and the temperature knob fully
anticlockwise.
2.
Unscrew the lever cover anticlockwise.
3.
Unscrew
anticlockwise, and remove the
temperature/flow knob.
4.
Unscrew the grub screw using the
2.5 mm hexagonal key and remove the
inner bush.
5.
Lift off the locknut trim and unscrew
the locknut in an anticlockwise
direction.
Removing the Concealing Plate Assembly
1.
Remove both flow and temperature
knob assemblies. Refer to Removing
the Knob Assembly for instructions.
2.
Unscrew the grub screw, securing the
RAC, using the 2.5 mm hexagonal key
provided. Remove the RAC.
3.
Unscrew and remove the wall clamp
nut, then remove the outer seal and
concealing plate.
the
lever
screw,
Flow Knob
31
Locknut
Inner
Bush
Temperature
Knob
Locknut
Trim
Grub
Screw
Lever
Lever
Screw
Cover
Concealing
Plate
Foam Outlet
Seal
RAC
Wall Clamp
Nut
Grub Screw