Mira FORM Installation & User Manual page 23

Shower control
Table of Contents

Advertisement

1.
Remove the temperature knob and locknut assemblies. Refer to section:
'Maintenance, Removing/Fitting Knob and Concealing Plate Assemblies'.
2.
Unlock and remove the temperature spindle. Use the 3 mm hexagonal key supplied
to undo the locking screw.
3.
Rotate the cartridge spindle until the required maximum blend temperature is
obtained at the discharge point (clockwise = decrease temperature).
When resistance is felt do not use force to turn any further, as this can damage
the internal parts.
4.
Refit the temperature spindle at the maximum temperature position and secure
with the locking screw.
5.
Refit the locknut and temperature knob assemblies.
6.
Rotate the temperature knob through its full range of movement to make sure
that the full range of water temperatures can be selected.
Cartridge
Temperature
Spindle
Spindle
Locking
Screw
Locknut
Maximum Temperature Setting
3 mm A/F
Hexagonal
Wrench
Locknut Trim
Grub
Screw
23
Lever Cover
and Screw
Inner Bush
Temperature
Knob

Hide quick links: