Mira Form Shower Control
The Mira Form shower control has separate controls for temperature and flow.

OPERATION

Turn the temperature lever anticlockwise
for warmer water or clockwise for cooler
water. The preset maximum temperature
can be adjusted as required to suit both
site conditions and the user's comfort. Refer
to section: 'Commissioning' for further
information on Maximum Temperature
Setting.
Turn the flow lever anticlockwise until the
desired force of water is obtained.
Note! When the Form shower control is
installed with a fully modulating multipoint
or combination type gas water heater, the
maintained mains water pressure, and
hence the flow, must be sufficient to keep
the heater ignited. Therefore, it is important
to ensure that the flow knob is fully open to
prevent variation in the hot water supply
temperature.