Reboot The Unit; Hard-Reboot The Unit From The Rear Panel; Soft-Reboot The Unit From The Http Interface - Comtech EF Data DT-4572 Installation And Operation Manual

X-band down converter
Hide thumbs Also See for DT-4572:
Table of Contents

Advertisement

DT-4572 X-Band Down Converter
Firmware Update

5.4.4.2 Reboot the Unit

5.4.4.2.1 Hard-reboot the Unit from the Rear Panel

Typical for either the standard AC unit or the optional DC unit:
1. From the unit rear panel, switch the power OFF, and then turn the power
back ON.
2. Verify the new firmware version has booted; for example, check the
firmware version displayed on the DT-4572 front panel:
SW VER X.X.X

5.4.4.2.2 Soft-reboot the Unit from the HTTP Interface

Do these steps from the HTTP Interface 'Config | Utility' page:
1. In the 'Perform Soft Reboot' section, click [Reboot Now]:
2. Wait while the DT-4572 reboots with the Current Active Firmware Image.
3. To load a second image, repeat the tasks described throughout Section
5.4.4.
The DT-4572 is now operating with its latest firmware. The firmware update
process is complete.
DT_4572